22
Electrical systems need to perform consistently in
boiler rooms and around furnaces and evaporators.
Many of these processes require heat tracing to
maintain elevated temperatures throughout water/
wastewater processing systems.
Excessive heat or cold can wreak havoc on an electrical
system, potentially causing critical components to fail.
Operations are challenged to:
r Prevent premature material aging due to prolonged heat
r Avoid material contraction and expansion due to ground frost
r Protect against physical damage from hail
Thomas & Betts offers numerous electrical systems
and devices that are designed to withstand and
insulate against severe temperatures.
Extreme Temperature Protection
52
®
4FSJFT )JHI 5FNQFSBUVSF -JRVJEUJHIU
'MFYJCMF .FUBM $POEVJU 'JUUJOHT
r Handle temperatures ranging from -60° to 150° C
r Steel or malleable iron construction, electro-zinc
plated and chromate coated for corrosion protection
r Available in 45°, 90° and straight versions
"59 -JRVJEUJHIU 'MFYJCMF .FUBM $POEVJU
r Performs in extreme temperature environments,
from -60° to 150° C
r Conduit sizes from
3
8
" to 4"
&YUSB )JHI 5FNQFSBUVSF /ZMPO $BCMF 5JFT
r For use in temperatures from -40° to 150° C
r Smooth body sheds contaminants
)FBWZ %VUZ 4UBJOMFTT 4UFFM $BCMF 5JFT
r For use in temperatures from -80° to 538° C
r Available in both Type 304 and Type 316 stainless steel
)JHI 5FNQFSBUVSF 8JSF +PJOUT BOE 5FSNJOBMT
r Wire joints and fluoropolymer-insulated terminals
rated for temperatures up to 150° C, 600V maximum
r Wire joints include a molded, one-piece nylon insulator,
rated UL94V-2
r Wire joints feature brazed copper sleeves that prevent
separation of connection during crimping
r Wire joints’ internal serrations enable cold flow
for increased conductivity and pull-out strength
4UBJOMFTT 4UFFM 'MFYJCMF $POEVJU 4ZTUFNT
r Supports temperatures of -50° C to 350° C for static
applications and -45° C to 250° C for moving applications
r Corrosion-resistant stainless steel construction
r Offers high flexibility and fatigue life
5NBY BOE &NBY $JSDVJU #SFBLFST
r Electronic trip mechanism, unaffected by ambient
temperature fluctuations
r 100% rated versions available
r 0–6,000A current range
T&B
®
'JUUJOHT
ATX Liquidtight Flexible
Metal Conduit and Fittings
5Z 3BQ
®
Extra-High Temperature
and Stainless Steel Ties
4UB ,PO
®
High-Temperature Wire
Joints and Terminals
"EBQUBnFY
®
Stainless Steel Flexible
Conduit Systems
ABB
Tmax and Emax
Circuit Breakers